Hexo Industries (M) Sdn Bhd
1-2-9, i-Avenue, Medan Kampung Relau 1, 11900 Bayan Lepas, Penang, Malaysia.
+6011-6528 1088
+604-611 1186
+6012-954 1088
+6012-558 2052
  +60129541088

Indonesia Branch
Jababeka Bizpark, Blok D/16, Jababeka Innovation Center, Pintu 6, Blok D/16, Cikarang, Bekasi, Jawa Barat 60292, Indonesia.

Singapore Branch
SpectrumSense Solutions
1 Scotts Road, #24-10 Shaw Centre, Singapore 228208.

Agilent / Varian PHD-4 Sniffer

Previous 1 / 7 Next

Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector Agilent / Varian PHD-4 Sniffer  Portable Sniffer Leak Detector


Agilent / (previously is Varian) PHD-4 Sniffer Helium Leak Detector

The Agilent / (previously is Varian) PHD-4 sniffer helium leak detector is able to detect very small leaks in objects that have a slight helium/air pressure inside. The lightweight and rugged sniffer is sensitive to helium concentrations as small as 2 ppm- equivalent to a leak rate of 5x 10-6 atm-cc/sec, far superior to the performance by other means of detecting leaks, such as bubble-testing. The PHD-4 sensitivity relies on Agilent’s proprietary and patented SIPD (Selective Ion Pump Detection) technology. Since it is controlled by a microprocessor, the PHD-4 is easy to use with no training required. All tuning and zeroing are handled automatically. 

Features
  • The PHD-4 weighs only 2,6 Kg (5.7 lbs) including the battery
  • Wide range of uses: Replaces or can be used with existing methods such as bubble test or pressure decay
  • State-of-the-art microprocessor control allows great simplicity of operation
  • Fully automatic start-up
  • Ready for test in less than 3 minutes
  • Excellent selectivity for helium allows you to read helium leaks and ignore all other gases
  • Helium sensitivity can be adjusted as required to minimize test costs and helium consumption
  • Can operate either on battery power or connected to an outlet line voltage
  • The display can be set to use any of four languages (English, French, Germany, or Italian)
Specifications
Tech Specs
 
Lowest detectable helium concentration 2 parts per million (ppm)
Smallest detectable leak 5 × 10-6 atm-cc/sec
5 × 10-6 mbar-l/sec
5 × 10-7 Pa-m3/sec
Response time <2 seconds
Recovery time (from 50 to 0 ppm) <10 seconds
Start-up time, including self-check 3 minutes (approximate)
Power requirements 12 VDC from battery pack, car battery, or transformer
Transformer power supply 110-240V 50-60 Hz
Sealed, detachable battery pack 4 hours of operation with full charge
Ambient storage temperature -20 to +60 °C (4 to 140 °F)
Ambient operating temperature -5 to +35 °C (20 to 95 °F)
Maximum relative humidity 90%
Weight, basic module with battery 5.7 lbs (2.6 kg)
Background suppression (zeroing) Automatic
Tuning Automatic

Order Information :

PHD-4 Complete Package            Part Number : 9694640
Travel Case includes 
• PHD-4 basic unit
• Spare battery
• Transformer/Battery charger (110-240 V)
• Carrying strap
• Probe set
• 15-pin I/O connector
• CD Instruction manual

PHD-4 Basic Package                   Part Number : 9694600
Includes 
• PHD-4 basic unit
• Transformer/Battery charger (110-240 V)
• Carrying strap
• 15-pin I/O connector
• CD Instruction manual

PHD-4 Replacement Part Kit        Part Number : 9694660
Includes 
• Sampling pump with fittings
• Probe with sampling line
• Tip probe filter
• Internal filter (kit of 5 units)

Accessories                                                                 Part Number
• Probe set                                                                     9693515
• Capillary leak with refillable reservoir and gauge        9693540
• Probe with 10 meter (30’) maximum sampling line     9693525
• Telescoping extension probe                                      9693520

Individual Replacement Parts                                    Part Number
• Spare battery                                                              SR03702609
• Power supply (110-240 V)                                          SR03702888
• Sampling pump with fittings                                       SR03702513
• Probe with sampling line                                            SR03702538
• Tip probe filter                                                            SR2890001201
• Internal filter (kit of 5 units)                                        SR03702959
• Carrying strap                                                            SR03702791
• 15-pin I/O connector                                                  SR03702894
• Travel Case (metal)                                                   SR03702890
• Protective Bag (canvas)                                            VSPHD4BAG
 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


Switch to Mobile Version
Subscribe Newsletter