Hexo Industries (M) Sdn Bhd
1-2-9, i-Avenue, Medan Kampung Relau 1, 11900 Bayan Lepas, Penang, Malaysia.
+6011-6528 1088
+604-611 1186
+6012-954 1088
+6012-558 2052
  +60129541088

Indonesia Branch
Jababeka Bizpark, Blok D/16, Jababeka Innovation Center, Pintu 6, Blok D/16, Cikarang, Bekasi, Jawa Barat 60292, Indonesia.

Singapore Branch
SpectrumSense Solutions
1 Scotts Road, #24-10 Shaw Centre, Singapore 228208.

Calibrated Leaks for Leak Detectors - Agilent / Varian

Previous 2 / 16 Next

Calibrated Leaks for Leak Detectors - Agilent / Varian Leak Detector Parts & Accessories Leak Detector Calibrated Leaks for Leak Detectors - Agilent / Varian Leak Detector Parts & Accessories Leak Detector Calibrated Leaks for Leak Detectors - Agilent / Varian Leak Detector Parts & Accessories Leak Detector


 
Calibrated Leaks for Leak Detectors - Agilent / Varian

Agilent offers a wide range of calibrated helium leaks. While a helium mass spectrometer's internal calibrated leak insures the accuracy of the instrument, the only way to calibrate an entire system is by mounting an external calibrated leak.
 

Product List

 
--

Calibrated helium leak, 10-10 atm cc/sec range, with 1.125 inch compression port

1 Each

   

Helium calibrated leak, 10-8 atm cc/sec range, normally open valve

1 Each

   

Features
  • Available in several ranges from 10–6 to 10–10 atm cc/sec
  • NW25 or 1 1/8' inlet flange
-
Calibrated Helium Leaks
Agilent offers helium leaks traceable to NIST standards for use in calibrating your leak detector. An NW25 or 1⅛'' OD
tube fitting and isolation valve are provided as standard on the external leaks. The 10-6/10-5 range reference helium leak
includes a pressure gauge and refill port for evacuation and sniff test calibration.
 
External
                   1⅛'' Compression
NW25               Port
F8473325      F8473320      10-6/10-5 std cc/sec range refillable sniffing/evacuation leak with pressure gauge and KF25 adapter
F8473321      F8473301      10-7 std cc/sec range, with valve
F8473322      F8473302      10-8 std cc/sec range, with valve
F8473323      F8473303      10-9 std cc/sec range, with valve
F8473324      F8473304      10-10 std cc/sec range, with valve

Internal, ⅛'' NPT Fitting (without valve)
K3264301                            10-7 std cc/sec range
K3264302                            10-8 std cc/sec range

Calibration
Calibration of existing leaks is done on an advance exchange basis. To order the recalibration service, simply add “GG” in front of the above part numbers.
Please leave your enquiry here, we will reply as soon as possible.